5012PN |
5102PN |
|||
Technical Specifications |
||||
Size Range | 0.5 - 25.0 μm | |||
Channel Sizes | Standard: 0.5, 5.0μm Optional: 0.5, 10.0μm |
|||
Counting Efficiency | 50% at the minimum detectable size | |||
Flow Rate | 0.1 CFM (2.83 LPM) | 1.0 CFM (28.3 LPM) | ||
Laser Source | Laser Diode | |||
Zero Count Level | <1 count / 5 minutes (per JIS) | |||
Concentration Limits | 2,000,000 particles / ft³ @ 5% coincidence loss | 500,000 particles / ft³ @ 5% coincidence loss | ||
Calibration | ISO 21051-4 compliant ISO 17025 Accredited | |||
Sample Output | Internally filtered to HEPA standards (>99.997% @ 0.3μm) | |||
Vacuum Requirements | Internal Vacuum Pump | |||
Air Flow | Internally Monitored and Controlled | |||
Communication Modes | 4-20mA Output | |||
LED Indicators | Power, Service | |||
Connector | 8-pin Phoenix | |||
External Pump Switch | 2-pin Phoenix dry-contact relay | |||
Enclosure | NEMA Style 316L Stainless Steel or Powder Coated Steel | |||
Power | 110 / 220 VAC, 50-60Hz or 24VDC 100W | |||
Dimensions | 10” (w) x 12” (h) x 6.9” (d) [25.4 x 30.4 x 14.9 cm] | |||
Weight | AC Model, 20 lbs (9 kg); DC Model, 19.5 lbs (8.85 kg) | |||
Environmental Conditions |
||||
Operating | 50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing | |||
Storage | 14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing | |||
Accessories |
||||
Included | Operating Manual on CD; AC or DC Power Input Connector Kit | |||
Optional | Printed Operating Manual; Data Cable; Sample Tubing; 24VDC 100W Power Adapter (DC Model) |
The 4 series family of Laskin-Nozzle aerosol generators are durable, portable, and reliable. Designed for testing filter systems ranging from small glove boxes to large cleanroom plenums, ATI Laskin Nozzle generators provide the ideal solution for creating a poly-dispersed, sub-micron aerosol to certify and qualify in-situ filter systems. End users include independent filter certifiers, government, and commercial nuclear facilities, pharmaceutical manufacturers, medical facilities, as well as other industrial applications.
Flexible and Adjustable
The 4B family of aerosol generators produce an industry standard true Laskin III-A repeatable aerosol and feature adjustable aerosol concentration output to meet multiple application requirements. These generators are used in conjunction with an aerosol photometer to measure the aerosol penetration of an individual filter or filter system, typically to identify, quantify and repair leaks.
SERVICE & CALIBRATION