รายละเอียดทางเทคนิค
LPC 0.1 μm (MODBUS) | LPC 0.1 µm (4-20mA) | LPC 0.2 μm (MODBUS) | LPC 0.2 μm (4-20mA) | LPC 0.3 μm (MODBUS) | LPC 0.3 μm (4-20mA) | LPC 0.5 μm (MODBUS) | LPC 0.5 μm (4-20mA) | |
Specifications |
||||||||
Size Range | 0.1 – 0.5 µm | 0.1 – 0.5 µm | 0.2 – 2.0 µm | 0.2 –2.0 µm | 0.3 – 3.0 µm | 0.3 – 3.0 µm | 0.5 – 100.0 µm | 0.5 – 100.0 µm |
Channel Sizes | Standard: 0.1, 0.2, 0.3, 0.5 µm | Standard: 0.1, 0.2μm; Optional: 0.1, 0.3µm; 0.1, 0.5µm |
Standard: 0.2, 0.3, 0.5, 1.0μm; 0.2, 0.5, 1.0, 2.0μm | Standard: 0.2, 0.3μm Optional: 0.2, 0.5μm; 0.2, 1.0μm; 0.2, 2.0μm |
Standard: 0.3, 0.5, 0.7, 1.0μm; 0.3, 0.5, 1.0, 3.0μm | Standard: 0.3, 0.5μm Optional: 0.3, 0.7μm; 0.3, 2.0μm; 0.3, 3.0μm |
Standard: 0.5, 0.7, 1.0, 2.0μm; 0.5, 1.0, 2.0, 3.0μm; 0.5, 1.0, 2.0, 5.0μm | Standard: 0.5, 1.0μm Optional: 0.5, 2.0μm; 0.5, 5.0μm |
Laser Source | Laser Diode | |||||||
Flow Rate | 100ml/min | |||||||
Calibration | NIST Traceable | |||||||
Data Storage | Rotating Buffer, 2000 Records | - | Rotating Buffer, 2000 Records | - | Rotating Buffer, 2000 Records | - | Rotating Buffer, 2000 Records | - |
Communication Modes | RS-232 via RJ45 to PC, RS485/Modbus | RS-232 via RJ45 to PC, 4-20mA | RS-232 via RJ45 to PC, RS485/Modbus | RS-232 via RJ45 to PC, 4-20mA | RS-232 via RJ45 to PC, RS485/Modbus | RS-232 via RJ45 to PC, 4-20mA | RS-232 via RJ45 to PC, RS485/Modbus | RS-232 via RJ45 to PC, 4-20mA |
LED Indicators | Power, Service, Sampling | Power and Service | Power, Service, Sampling | Power, Service | Power, Service, Sampling | Power, Service, Sampling | Power, Service, Sampling | Power, Service, Sampling |
Supporting Software | LMS Express, Express RT and RT+, LMSNet | |||||||
Concentration Limit | 64,000 counts/ml @ 5% Coincidence Error | 4,000 counts/ml @ 5% Coincidence Error | ||||||
External Alarm Output | Normal Open Dry Contact Rated 0 – 60v AC/DC 1 Amp | |||||||
Enclosure | Stainless Steel | |||||||
Sample Inlet/Outlet Connection | 1/4" Flaretek™ | |||||||
Sample Temperature | 32 - 302°F (0 – 150 °C) | |||||||
Sample Pressure | 150 PSI | |||||||
Wetted Surface Materials | Quartz, PTFE, PFA | |||||||
Power | 24V DC | |||||||
Dimensions | 5.7"(L) x 5.2"(W) x 3"(H) [14.47 x 13.2 x 7.6 cm] | |||||||
Weight | 3.5 lbs (1.58 kg) | |||||||
Environmental Conditions |
||||||||
Operating | 50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing | |||||||
Storage | 14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing | |||||||
Accessories |
||||||||
Included | Operating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Cleaning Brush | Operating Manual on CD; Power Supply; Flow Cell cleaning brush; Micro90® solution; tubing. | Operating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Flaring Kit; Cleaning Brush | Operating Manual on CD; Power Supply; tubing; Flow Cell cleaning brush; Micro90® Solution | Operating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Flaring Kit; Cleaning Brush | Operating Manual on CD; Power Supply; tubing; Flow Cell cleaning brush; Micro90® Solution | Operating Manual on CD; Power Supply; Micro90® cleaning solution; Sample Tubing; Cabling; Flaring Kit; Cleaning Brush | Operating Manual on CD; Power Supply; tubing; Flow Cell cleaning brush; Micro90® Solution |
Optional | Printed Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT; LMSNet software | Printed Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket. | Printed Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT software; LMSNet software | Printed Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket. | Printed Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT software; LMSNet software | Printed Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket. | Printed Operating Manual; Network Adapter; Wireless Network Adapter; Flow Control device; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flowmeter - Teflon™ PFA; REMOTE Mounting Bracket; LMS Express, Express RT software; LMSNet software | Printed Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket. |
ต้องการใบเสนอราคา
Incorporating the latest in laser optical particle counting technology and utilizing full stream volumetric particle counting technology, Lighthouse designed the Remote Liquid Particle Counter 0.3μm (Modbus Output) for continuous trouble-free operation.
With a minimum sensitivity range of 0.3 μm and a flow rate of 100 mL/min, the Remote Liquid Particle Counter 0.3 μm provides real-time continuous data collection at a cost-effective price per point.
This compact liquid particle counter provides versatile mounting options and can be installed where space is at a premium.
The Remote Liquid Particle Counter 0.3μm integrates seamlessly into large facility monitoring and management systems using RS-485 MODBUS.
Key Features:
- 0.3– 3.0 μm particle size ranges
- 100 mL/min flow Rate
- 4 channels of simultaneous data
- RS-485 Modbus Output
- Stainless Steel Enclosure
- Status Indicators
- Interfaces with Facility Monitoring Systems
- Compact Size
- Designed for Reliability
Type | Part # | ตำแหน่ง | ขนาดกระดาษ | ขนาดไฟล์ | ดาวน์โหลด |
---|---|---|---|---|---|
คู่มือการใช้งาน | 248083227-1 R8 | Remote LPC 0.1μm, 0.2μm, 0.3μm, 0.5μm (MODBUS Output) | Letter | 990.4 KB | ดาวน์โหลด |
ข้อมูลผลิตภัณฑ์ | 191023 | Remote LPC 0.1µm, 0.2µm, 0.3µm, 0.5µm | Letter | 529.7 KB | ดาวน์โหลด |