This is just filler text….

Internal and external sensor options are available

The Cobalt 2 Digital Temperature sensors are read directly by the Cobalt 2 signal processor to ensure consistent accuracy over time. Typical application are on refrigerators, cold rooms or freezers (-40 – +80°C) / incubators and water baths (-40 – +120°C). Data is logged locally in Cobalt 2 memory and transmitted wirelessly to a host computer at programmable intervals. Alerts can be sent automatically as configured in the software.

Features:

  • Range -40°C to +80°C and -40°C to +120°C
  • Digital temperature sensors
  • On-board memory for 3.000 measurements

The Cobalt differential pressure module contains two pressure sensors, which makes it possible to compare the relative pressure between two zones, for example, the door between cleanrooms.
This module is typically placed in the room in which the ambient pressure is considered as “normal.” The Cobalt differential pressure module is particularly suitable for use in monitoring “clean” and “dirty” laboratory areas.

Features

  • Range -500 to +500 Pa.
  • Overall accuracy +/- 2 Pa at a range of -50 Pa to +50 Pa.
  • Including display and calibration on 5 points.

3-wire, Class B PT100 sensors

Cobalt 2 modules are available with three types of precision PT100 sensors to cover a wide range of applications, from liquid nitrogen tanks to high-temperature kilns. Each external analog sensor is connected to the Cobalt 2 module via a robust cable designed for the target temperature range. 

Typical application are on ultra low freezers (-100 – +150°C) / LN2 and cryogenic freezers (-200 – +50°C) / ovens (+100 to + 350°C). Data is logged locally in Cobalt 2 memory and transmitted wirelessly to a host computer at programmable intervals. Alerts can be sent automatically as configured in the software.

Features:

  • Range -100°C to +150°C, -200°C to +50°C and +100°C to +350°C
  • 3-wire, Class B PT100 sensors 
  • On-board memory for 3.000 measurements

Monitor both temperature and humidity with a single sensor

Transmitter Cobalt 2 ideal for monitoring the ambient environment in laboratories, storage areas, and mission-critical facilities. The Cobalt 2 Humidity & Temperature module is a dual-function device that logs both relative humidity (RH) levels and temperature. Typical applications are in incubators, stability cabinets, and ambient room environments. 
The Cobalt 2 module collects and stores humidity (RH) and temperature readings from the connected sensor module at regular intervals and transmits them to a monitoring system.

Features:

  • Range -40°C to +100°C and 0% to 99.9% RH
  • External digital dual sensor (with PTFE protection filter)
  • Digital temperature (resolution 0.0625°C) / relative humidity sensor (resolution 0.025% RH)