TECHNISCHE DETAILS

  1100 LD 3100 5100 3200 5200 3350 5350 Boulder Counter

Specifications

Size Range 0.1 - 1.0 μm
Optional ranges up to 5.0 µm
0.3 - 25.0μm 0.5 - 25.0μm 0.3 - 25.0 um 0.5 - 25.0 um 0.3 - 25.0 µm 0.5 - 25.0 um 5.0 - 100.0 um
Channel Sizes Standard: 0.10, 0.15, 0.2, 0.25, 0.3, 0.5, 0.7, 1.0μm Standard: 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm
Standard: 0.3, 0.5, 1.0, 5.0, 10.0, 25.0 µm
8-Channel: 0.3, 0.5, 0.7, 1.0, 3.0, 5.0,7.0,10.0 µm
Standard: 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm
Standard: 0.5, 1.0, 3.0, 5.0, 10.0, 25.0 µm
8-Channel: 0.5, 0.7, 1.0, 2.0, 3.0, 5.0, 7.0,10.0 µm
Standard: 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm
Standard: 0.3, 0.5, 1.0, 5.0, 10.0, 25.0 µm
8-Channel: 0.3, 0.5, 0.7, 1.0, 3.0, 5.0, 7.0, 10.0 µm
8-Channel Optional: 0.3, 0.5, 0.7, 1.0, 5.0, 7.0, 10.0, 25.0 µm
Standard: 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm
Standard: 0.5, 1.0, 3.0, 5.0, 10.0, 25.0 µm
8-Channel: 0.5, 0.7, 1.0, 2.0, 3.0, 5.0, 7.0, 10.0 µm
8-Channel Optional: 0.5, 1.0, 2.0, 3.0, 5.0, 7.0, 10.0, 25.0 µm
Standard: 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm
Optional: 0.3, 0.5, 1.0, 5.0, 10.0, 25.0 µm
Standard: 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm
Optional: 0.5, 1.0, 3.0, 5.0, 10.0, 25.0 µm
Standard: 5.0, 10.0, 25.0, 40.0, 50.0,100.0µm 
Flow Rate 1.0 CFM (28.3 LPM) 50 LPM 100 LPM 28.3 LPM
Counting Efficiency 50% @ 0.1μm; 100% @ sizes > 0.15μm Per JIS B 9921 and ISO 21501-4 50% @ 0.3 µm; 100% @ sizes
> 0.45 µm
50% @ 0.5 um; 100% @ sizes
> 0.75 µm
50% @ 0.3 µm; 100% @ sizes > 0.45 µm 50% @ 0.5 um; 100% @ sizes > 0.75 µm 50% @ 0.3 µm; 100% @ sizes > 0.45 µm 50% @ 0.5 µm; 100% @ sizes > 0.75 µm 50% @ 5.0 um
Concentration Limits 500,000 Particles / ft3 (17,150,000 / m3) @ 5% Coincidence Loss 1,000,000 particles/ft3
(35,300,000/m3) @ 10% coincidence loss
Suitable for ISO classes 1-8 cleanrooms
700,000 particles/ft3 (24,710,000/m3) @ 10% coincidence loss
Suitable for ISO classes 1-8 cleanrooms
400,000 particles/ft3 (14,120,000/m3)
@ 10% coincidence loss
Suitable for ISO classes 1-8 cleanrooms
500,000 particles/ft3 @ 5% coincidence loss 
Light Source Long Life Laser Diode Extreme Life Laser Diode Technology with >20-year Mean Time To Failure (MTTF)
Dimensions 14.65"Lx8.0"Wx10.4"H (37x20x26cm) 9.5"Lx8.0"Wx10.2"H (24.13x20.32x25.9cm) 14.65"Lx8.0"Wx10.4"H (37x20x26cm) 9.5"Lx8.0"Wx10.2"H (24.13x20.32x25.9cm)
Weight With battery: 23.55 lbs (10.68 kg)
Without battery: 20.45 lbs (9.28 kg)
With battery: 13.40 lbs (6.08 kg)
Without battery: 12.00 lbs (5.44 kg)
With battery: 20.90 lbs (9.48 kg)
Without battery: 17.80 lbs (8.07 kg)
With battery: 26.15 lbs (11.86 kg)
Without battery: 23.05 lbs (10.46 kg)
With battery: 13.40 lbs (6.08 kg)
Without battery: 12.00 lbs (5.44 kg)
Zero Count Level < 1 count / 5 minutes (per JIS B 9921)
Calibration Meets ISO 21501-4 Calibration using NIST Traceable PSL Spheres, DMA and Condensation Particle Counter
Count Modes Automatic, Manual, Beep, Concentration, Cumulative/Differential, Real Time (with LMSNet or LMS Express RT software)
Data Storage 3,000 Sample Records, Rotating Buffer (particle and environmental data with location and time)
Communication Modes USB, Ethernet, RS-485 and Secure Data Transfer (LSDT) to and Storage on USB Flash Drive
Supporting Software LMS Express and Express RT; LMS Pharma
Environmental Sensors Optional (up to 4) temperature/relative humidity, air velocity, differential pressure or others
Touch Screen Display 5.7-inch (14.47 cm) Color TFT Touch Screen Display
Reports Pass/Fail Report Wizard for ISO-14644-1, EU GMP Annex 1 and FS-209 Report Formats
Alarms Integrated alarm buzzer and external alarm connector. Alarms on counts, low battery, sensor failure
Sample Output Internally Filtered to 100% @ 0.1μm, Optional HEPA Filtration for Cooling System Exhaust Internally filtered to HEPA standards (>99.97% @ 0.3μm)
Vacuum Source Internal closed-loop controlled pump. Allows the use of 3/8" ID sample tubing of up to 12 meters (40 feet) @ 50 & 100LPM
Enclosure Stainless Steel
Power 100-240 VAC, 50-60 Hz, External AC/DC Adapter
Battery Optional: Li-Ion, Removable & Rechargeable (typical recharge time 7.5 hours)
Languages English (U.S.), French, German, Italian, Spanish, Chinese, Russian, Japanese, Korean

Environmental Conditions

Operating 50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing
Storage 14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing

Accessories

Included Operating Manual on CD; Isokinetic Sample Probe with Tripod and Tubing; Purge Filter; Power Cable and Spare Fuse; LMS XChange and Express Software; Printer; Printer Paper
Optional Printed Operating Manual; Network Adapter; Wireless Network Adapter; Internal Removeable, Rechargeable Battery; Carrying Case with Wheels; Cleanroom Cart; Temperature/Relative Humidity Probe; Air Velocity Probe; Differential Pressure Probe; Filter Scanning Probe; High Pressure Difuser; 32-Port Universal Manifold; LMS Express RT Software; LMSNet Software; Validation Documentation Wireless Network Adapter; Removable Rechargeable Li-Ion Battery; Carrying Case with Wheels; Temperature/Relative Humidity Probe; Differential Pressure Probe; Intelligent Filter Scanning Probe; Air Velocity Probe; Spare Removable
Rechargeable Li-Ion Battery; External Battery Charger; LMS Express, RT Software; LMS Pharma Edition Software; LMS Standard Software; Validation Documentation; Printed Operating Manual; Cleanroom Cart

OFFERTE AANVRAAG

Voornaam (*)
Achternaam (*)
Bedrijf (*)
E-mailadres (*)
Telefoonnummer (*)
Adres (*)
Bericht (*)
Veiligheidscode
Security Code ImageRefresh Button
(*)
(*) Verplichte velden

(INSTRUCTIE) VIDEO'S

Solair | Configure Sample Settings
Solair | Configure Alarm Settings
Solair | Configure Security Settings
Solair 3100 | Sample Setting Parameters
Solair 3100 | Reports Function
Solair 3100 | Locations Function

Ongekende veelzijdigheid

Uw Solair Particle Counter biedt veel mogelijkheden

De Solair is de beste draagbare deeltjesteller op de markt, en kan verbonden worden met een manifold en gebruikt worden in een realtime monitoring systeem. Met de aanvulling van een ScanAirPro Set kunnen filter integriteitstesten uitgevoerd worden. Een optionele high pressure controller maakt metingen in (ultraschone) gassen mogelijk. Hiermee beschikt u over ’s werelds meest veelzijdige draagbare deeltjesteller

Deeltjestellers voor elke toepassing

PRODUCT CONFIGURATOR

Filter Models and Find Your Model Number

1st Selection
Minimum Channel Size
2nd Selection
Flow Rate
 
 
Your Generated Model Number by Selection : **0
Solair 1100LD

Solair 1100LD

The SOLAIR 1100LD (Laser Diode) leads the industry as the first of its kind portable particle counter with 0.1 micron sensitivity and...

Solair 3100

Solair 3100

  Number 1 in Versatility The SOLAIR 3100 is the most versatile particle counter on the market today.  Whether...

Solair 3200

Solair 3200

The SOLAIR 3200 incorporates our extreme life laser diode technology sensor to produce the industry’s longest laser diode life of 20+...

Solair 3350

Solair 3350

The SOLAIR 3350 incorporates our extreme life laser diode technology sensor to produce the industry’s longest laser diode life of 20+...

Solair 5100

Solair 5100

  Number 1 in Versatility The SOLAIR 5100 is the most versatile particle counter on the market today.  Whether you are...

Solair 5200

Solair 5200

The SOLAIR 5200 incorporates our extreme life laser diode technology sensor to produce the industry’s longest laser diode life...

Solair 5350

Solair 5350

The SOLAIR 5350 incorporates our extreme life laser diode technology sensor to produce the industry’s longest laser diode life...

Boulder Counter

Boulder Counter

The SOLAIR Boulder Counter incorporates our Extreme Life Laser Diode Technology sensor to produce the industry’s longest...