TECHNISCHE DETAILS

  2016 3016 5016 3016 IAQ

Specifications

Size Range 0.2 - 2.0 μm 0.3 - 25.0 μm 0.5 - 25.0 μm 0.3 - 10.0 μm
Channel Sizes 0.2, 0.3, 0.5, 0.7, 1.0, 2.0 μm Standard: 0.3, 0.5, 0.7, 1.0, 2.0, 5.0 μm
Standard: 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 μm
Standard: 0.3, 0.5, 0.7, 1.0, 2.5, 5.0 μm
Standard: 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm
Optional: 0.3, 0.5, 1.0, 5.0, 10.0, 25.0 μm
Standard: 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 μm
Optional: 0.5, 1.0, 3.0, 5.0, 10.0, 25.0 μm
Standard: 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm
Counting Efficiency 50% @ 0.2 μm; 100% for particles > 0.3 μm (per ISO 21501-4) 50% @ 0.3 μm; 100% for particles > 0.45 μm (per ISO 21501-4) 50% @ 0.5 μm; 100% for particles > 0.75 μm (per ISO 21501-4) 50% @ 0.3 μm; 100% for particles > 0.45 μm (per ISO 21501-4)
Flow Rate 0.1 CFM (2.83 LPM)
Laser Source Extreme Life Laser Diode with >20 Years MTTF
Zero Count Level <1 count / 5 minutes (per ISO 21501-4)
Concentration Limits 4,000,000 particles / ft³ @ 5% coincidence loss
Calibration Meets ISO 21501-4 Calibration using NIST Traceable PSL Spheres, DMA and Condensation Particle Counter
Count Modes Automatic, Manual, Beep, Concentration, Cumulative/Differential Automatic, Manual, Beep, Concentration, Cumulative/Differential, Mass Concentration
Data Storage 3,000 Sample Records, Rotating Buffer (includes particle and environmental data, location and time)
Communication Modes RS-232 via RJ-45 to a PC or an Optional Printer
Supporting Software LMS XChange; LMS Express; LMS Express RT; LMS Pharma; LMS Standard; CRQWin
Environmental Sensors Temperature/Relative Humidity Probe:0-150°F (-17.8 to 65.6°C) ±1.8°F @ 77°F, 0-100% ± 5% @ 33%
Touch Screen Display 3.5” (8.89 cm), Color TFT
Reports FS-209E, ISO-14644-1 & EC GMP
Mass Concentration - 1 μg/m³ Approximate Mass Concentration
Alarms Internal, Adjustable Alarm Buzzer. Alarms on Counts, Low Battery or Sensor Failure
Sample Inlet Isokinetic Sampling Probe
Sample Output Internally Filtered to HEPA Standards (>99.97% @ 0.3 μm)
Vacuum Source Internal Pump, Automatic Flow Control
Enclosure High Impact Injection Molded Plastic
Power External Power Supply: 12VDC, 1.25A
Battery Li-Ion, Removable & Rechargeable
Dimensions 8.75” (l) x 5.0” (w) x 2.5” (h) [22.23 x 12.7 x 6.35 cm]
Weight 2.2 lb (1kg)
Languages English (U.S.), Deutsch, Espanol, Italiano, Francois, Russian, Japanese, Korean and Chinese.

Environmental Conditions

Operating 50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing
Storage 14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing

Accessories

Included Operating Manual on CD; Removable Battery; Direct Mount Isokinetic Sample Probe; Purge Filter; Temperature / Relative Humidity Probe; Power Supply; Power Cord; LMS XChange and LMS Express Software
Optional Carrying Case; Isokinetic Sample Probe with 6 ft. tubing (extends Isokinetic sample input); Additional Li-Ion Batteries; External Battery Charger w/ AC & Car Adapter; Thermal Printer and Cable; Mini Manifold; Printed Operating Manual

OFFERTE AANVRAAG

Voornaam (*)
Achternaam (*)
Bedrijf (*)
E-mailadres (*)
Telefoonnummer
Adres (*)
Land (*)
Branche (*)
Bericht (*)

Veiligheidscode
Security Code ImageRefresh Button
(*)
(*) Verplichte velden
Handheld Particle Counter 5016

The ergonomically designed and lightweight Lighthouse Handheld 5016 particle counter features a minimum sensitivity of 0.5 μm and is the most advanced handheld particle counter on the market. Providing up to 6 particle size channels of simultaneous counting, the Lighthouse Handheld 5016 can display cumulative and differential particle count data as well as Temperature/Relative Humidity data on the fast and easy to read color touch screen. Removable batteries and an optional charger help to maximize the Handheld 5016's uptime. Data is easily downloaded using the Lighthouse Data Transfer Software. The Handheld 5016 can be used as a mobile particle monitor or become a part of a large facility monitoring and management system.

Key Features:

  • 0.5 - 25 μm Size Range
  • 0.1 CFM (2.83 LPM) Flow Rate
  • View 6 Particle Sizes Simultaneously
  • Designed for ISO 21501-4 Compliance
  • Unit-to-Unit Accuracy and Repeatability
  • Bright 3.5” (8.89 cm) Color Touch Screen Display
  • Removable / Rechargeable Li-Ion Battery
  • Large Memory for Storing Data (3,000 samples)
  • Concentration Limit - 4,000,000 / ft3
  • Temperature/Relative Humidity Probe Included
  • Alphanumeric Location Labels
  • Test Wizard for Cleanroom Pass/Fail Reports:
  • FS-209E, ISO-14644-1 or EU GMP Annex 1
  • 50-record Configurable Recipe Database
  • Easily Configurable Interface with Zoom Capability
  • Internal Audible Alarm
  • Ergonomically Designed
  • Lightweight
  • Open Architecture Connectivity with OPC Server

INSTRUMENT FILES
Type Part # Title Paper Size File Size Download
Brochure - Handheld 2016, 3016, 3016-IAQ, 5016 Letter 4.46 MB DOWNLOAD
Datasheet - Handheld 2016, 3016, 3016-IAQ, 5016 Letter 1.26 MB DOWNLOAD
Operating Manual 248083400-1 R7 Handheld 2016, 3016, 5016 Gen F Letter 5.36 MB DOWNLOAD