{"id":9777,"date":"2022-12-14T05:48:00","date_gmt":"2022-12-14T05:48:00","guid":{"rendered":"https:\/\/www.golighthouse.com\/en\/?post_type=knowledge-center&#038;p=9777"},"modified":"2022-12-20T19:49:20","modified_gmt":"2022-12-20T19:49:20","slug":"en-iso-14698-to-en-17141","status":"publish","type":"knowledge-center","link":"https:\/\/www.golighthouse.com\/en\/blog\/en-iso-14698-to-en-17141\/","title":{"rendered":"Getting From EN ISO 14698 to EN 17141"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"9777\" class=\"elementor elementor-9777\" data-elementor-post-type=\"knowledge-center\">\n\t\t\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-top-section elementor-element elementor-element-9c38355 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"9c38355\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-996f47b\" data-id=\"996f47b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f0499e6 elementor-widget elementor-widget-text-editor\" data-id=\"f0499e6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\tAfter 17 years of no revisions, a formal vote in 2019 replaced EN ISO 14698 with EN 17141 in Europe. Shortly after, confusion ensued. While CEN\/TC243 (the technical committee in CEN) had found EN ISO 14698 obsolete and replaced it with a new guidance (under a new number, to avoid confusion), old versions still existed and the international standard, ISO 14698, remained in place. Now, there is a movement to replace ISO 14698 with the standards set forth in EN 17141 to consolidate documents and decrease confusion.\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-af56eaa elementor-widget elementor-widget-heading\" data-id=\"af56eaa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Microbiological Contamination Control Standards As They Exist Today\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-48b0c1c elementor-widget elementor-widget-text-editor\" data-id=\"48b0c1c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">This can be a convoluted topic, so it is best to gain some clarity up front on who is making what decisions &#8211; and which standards impact you.<\/span><\/p><p><span style=\"font-weight: 400;\">ISO\/TC209 is the technical committee in the ISO community who makes decisions related to cleanrooms and associated controlled environments. They manage the ISO 14644 family of cleanroom related standards, including ISO 14698-1 and -2, the standards around biocontamination control.\u00a0<\/span><\/p><p><span style=\"font-weight: 400;\">On the other hand, CEN\/TC243 is the technical committee in CEN. It often does mirror work of ISO\/TC209, as it has shared members. The Vienna Agreement allows for sharing standard work between the two committees, as well as parallel voting.<\/span><\/p><p><span style=\"font-weight: 400;\">From 2009 to 2014, a committee attempted to address the issues within ISO 14698, but there were too many internal clashes over the purpose of the document. Some wanted to focus on classification, while others maintained the emphasis needs to strictly be on monitoring. They were not able to resolve this conflict and, after 5 years, the committee disbanded. (Spoiler alert: this work is now being continued and the emphasis has been placed on monitoring &#8211; not classification).\u00a0<\/span><\/p><p><span style=\"font-weight: 400;\">Currently, ISO 14698-1 and -2 were last revised in 2003. In March 2020, there was a Systematic Review (SR) vote to withdraw ISO 14698-1 and -2. In Europe, this was replaced by <\/span><a href=\"https:\/\/www.golighthouse.com\/en\/blog\/what-is-en-17141\/\"><span style=\"font-weight: 400;\">EN 17141<\/span><\/a><span style=\"font-weight: 400;\"> in August 2020. There has been a push for ISO to adopt these standards at an international level to avoid confusion and consolidate standards into one publication.\u00a0<\/span><\/p><p><span style=\"font-weight: 400;\">In response to this request, ISO\/TC209 has resumed the work of the original committee from 2004 in cooperation with CEN\/TC243 to put forth an international, cohesive standard.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3b32c1e elementor-widget elementor-widget-heading\" data-id=\"3b32c1e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Challenges That Come With Microbiological Contamination Control Standards\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bc7698b elementor-widget elementor-widget-text-editor\" data-id=\"bc7698b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">The journey to get to a comprehensive, singular standard is not simple. While particle counting is far from easy, microbiological contamination is a different level of complexity. It deals with living organisms that are not easy to recover, measure, or observe in the first place. We call these the unseen enemies.<\/span><\/p><p><span style=\"font-weight: 400;\">Microbiological contamination also presents a wide range of issues that depend on a number of variables, including how the cleanroom functions. Humans are the primary contributor to this issue, accounting for 70% to 80% of contamination within a cleanroom. Even with a shift of focus towards robotics and automation, with less human presence in the cleanroom, it is inevitable that some level of human influence will be present.<\/span><\/p><p><span style=\"font-weight: 400;\">Moreover, different stakeholders and industries present a number of unique challenges. The life science industry is looking for sterility, but the food industry needs safety. The healthcare industry, on the other hand, is primarily concerned with infection control.<\/span><\/p><p><span style=\"font-weight: 400;\">There is no one size solution to solve all these problems, which is why the new technical committee has stakeholders from every industry, as well as subject matter experts, to represent the unique difficulties their division is facing.\u00a0<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d70030c elementor-widget elementor-widget-heading\" data-id=\"d70030c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Issues Found In EN ISO 14698\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8e1c4b4 elementor-widget elementor-widget-text-editor\" data-id=\"8e1c4b4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">While the very topic of microbiological contamination control is complex, EN ISO 14698 presented its own host of contradictions and problems. The lack of updates over the last 17 years in the face of new regulations, guidelines, and technological advances did not help.<\/span><\/p><p><span style=\"font-weight: 400;\">For example, ISO 14698 is not in line with the current ISO 14644 approach. There are no principles for establishing and demonstrating control, as well as a lack of clarity on classification vs monitoring. There is a profound lack of checklists for \u201cthings to consider\u201d, as well as a slew of challenges in real time measurement versus traditional indirect methods for sampling, recovery, incubation, and enumeration. ISO 14698 also does little to help the different industries with their wide array of problems.\u00a0<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-325e33d elementor-widget elementor-widget-heading\" data-id=\"325e33d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">EN 17141\u2019s New Approach To Biological Contamination Control\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-40460a4 elementor-widget elementor-widget-text-editor\" data-id=\"40460a4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">With these issues and complications in mind, EN 17141 proposes a revised standard with the goal to find international acceptance. It focuses heavily on control and monitoring, not classification. This is done through a risk assessment and a plan that focuses on establishing then demonstrating control. It provides an easier and more practical standard to use in different industries, reinforcing best practices while leveraging existing guidelines.<\/span><\/p><p><span style=\"font-weight: 400;\">Most importantly: it creates a single standard.<\/span><\/p><p><span style=\"font-weight: 400;\">This standard keeps what works from ISO 14698 while reinforcing risk assessment, impact, and mitigation (this is Quality Risk Management or QRM). It aligns with the changes in the recently published <\/span><a href=\"https:\/\/www.golighthouse.com\/en\/blog\/gmp-annex-1-2022-update-breakdown-part-1-629\/\"><span style=\"font-weight: 400;\">GMP Annex 1<\/span><\/a><span style=\"font-weight: 400;\"> and adapts to evolving technologies. It removes unnecessary materials, including liquids, biocontamination in textiles, and validation in laundering. It also removes some issues, such as endotoxins, viruses, and prions. Meanwhile, it adds guidance for medical device manufacturers.\u00a0<\/span><\/p><p><span style=\"font-weight: 400;\">The standard also\u2026<\/span><\/p><ul><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Reviews scope of microbiological continuum.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Gives an independent review and assessment of current indirect measurement methods, which includes the importance of the d50.\u00a0<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Recognizes the roles of other standards without replicating them.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Distinguishes between culturable and viable.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Highlights the differences between cleanrooms and controlled environments, with according guidance.<\/span><\/li><\/ul><p><span style=\"font-weight: 400;\">But how does EN 17141 differ from EN ISO 14698? How does it provide customized support to different industries? We\u2019ll answer those questions (and more) in our next blog! Create your free <\/span><a href=\"https:\/\/www.golighthouse.com\/en\/knowledge-center-login\/?return=%2Fen%2Fknowledge-center%2F\"><span style=\"font-weight: 400;\">Knowledge Center<\/span><\/a><span style=\"font-weight: 400;\"> account to be the first to see that blog.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"featured_media":9778,"template":"","kc_format":[63],"kc_topics":[79],"class_list":["post-9777","knowledge-center","type-knowledge-center","status-publish","has-post-thumbnail","hentry","kc_format-blog","kc_topics-standards-training"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Getting From EN ISO 14698 to EN 17141<\/title>\n<meta name=\"description\" content=\"EN ISO 14698 was voted to be obsolete and replaced with EN 17141. Now, there is an international push to adopt the singular standards put forward in EN 17141.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.golighthouse.com\/en\/knowledge-center\/en-iso-14698-to-en-17141\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"LWS Knowledge Center\" \/>\n<meta property=\"og:description\" content=\"EN ISO 14698 was voted to be obsolete and replaced with EN 17141. Now, there is an international push to adopt the singular standards put forward in EN 17141.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.golighthouse.com\/en\/knowledge-center\/en-iso-14698-to-en-17141\/\" \/>\n<meta property=\"og:site_name\" content=\"Lighthouse Worldwide Solutions\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/Lighthouse.Worldwide.Solutions\" \/>\n<meta property=\"article:modified_time\" content=\"2022-12-20T19:49:20+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.golighthouse.com\/en\/wp-content\/uploads\/2022\/12\/Changing-Standards-Smaller.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"714\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.golighthouse.com\\\/en\\\/knowledge-center\\\/en-iso-14698-to-en-17141\\\/\",\"url\":\"https:\\\/\\\/www.golighthouse.com\\\/en\\\/knowledge-center\\\/en-iso-14698-to-en-17141\\\/\",\"name\":\"Getting From EN ISO 14698 to EN 17141\",\"isPartOf\":{\"@id\":\"http:\\\/\\\/www.golighthouse.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.golighthouse.com\\\/en\\\/knowledge-center\\\/en-iso-14698-to-en-17141\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.golighthouse.com\\\/en\\\/knowledge-center\\\/en-iso-14698-to-en-17141\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.golighthouse.com\\\/en\\\/wp-content\\\/uploads\\\/2022\\\/12\\\/Changing-Standards-Smaller.png\",\"datePublished\":\"2022-12-14T05:48:00+00:00\",\"dateModified\":\"2022-12-20T19:49:20+00:00\",\"description\":\"EN ISO 14698 was voted to be obsolete and replaced with EN 17141. Now, there is an international push to adopt the singular standards put forward in EN 17141.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.golighthouse.com\\\/en\\\/knowledge-center\\\/en-iso-14698-to-en-17141\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.golighthouse.com\\\/en\\\/knowledge-center\\\/en-iso-14698-to-en-17141\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.golighthouse.com\\\/en\\\/knowledge-center\\\/en-iso-14698-to-en-17141\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.golighthouse.com\\\/en\\\/wp-content\\\/uploads\\\/2022\\\/12\\\/Changing-Standards-Smaller.png\",\"contentUrl\":\"https:\\\/\\\/www.golighthouse.com\\\/en\\\/wp-content\\\/uploads\\\/2022\\\/12\\\/Changing-Standards-Smaller.png\",\"width\":1000,\"height\":714},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.golighthouse.com\\\/en\\\/knowledge-center\\\/en-iso-14698-to-en-17141\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.golighthouse.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Knowledge Center\",\"item\":\"https:\\\/\\\/www.golighthouse.com\\\/en\\\/knowledge-center\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Getting From EN ISO 14698 to EN 17141\"}]},{\"@type\":\"WebSite\",\"@id\":\"http:\\\/\\\/www.golighthouse.com\\\/en\\\/#website\",\"url\":\"http:\\\/\\\/www.golighthouse.com\\\/en\\\/\",\"name\":\"Lighthouse Worldwide Solutions\",\"description\":\"\",\"publisher\":{\"@id\":\"http:\\\/\\\/www.golighthouse.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"http:\\\/\\\/www.golighthouse.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"http:\\\/\\\/www.golighthouse.com\\\/en\\\/#organization\",\"name\":\"Lighthouse Worldwide Solutions\",\"url\":\"http:\\\/\\\/www.golighthouse.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"http:\\\/\\\/www.golighthouse.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.golighthouse.com\\\/en\\\/wp-content\\\/uploads\\\/2022\\\/11\\\/211317000-1-R1-LWS-Logo-Black-on-White.png\",\"contentUrl\":\"https:\\\/\\\/www.golighthouse.com\\\/en\\\/wp-content\\\/uploads\\\/2022\\\/11\\\/211317000-1-R1-LWS-Logo-Black-on-White.png\",\"width\":217,\"height\":36,\"caption\":\"Lighthouse Worldwide Solutions\"},\"image\":{\"@id\":\"http:\\\/\\\/www.golighthouse.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/Lighthouse.Worldwide.Solutions\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Getting From EN ISO 14698 to EN 17141","description":"EN ISO 14698 was voted to be obsolete and replaced with EN 17141. Now, there is an international push to adopt the singular standards put forward in EN 17141.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.golighthouse.com\/en\/knowledge-center\/en-iso-14698-to-en-17141\/","og_locale":"en_US","og_type":"article","og_title":"LWS Knowledge Center","og_description":"EN ISO 14698 was voted to be obsolete and replaced with EN 17141. Now, there is an international push to adopt the singular standards put forward in EN 17141.","og_url":"https:\/\/www.golighthouse.com\/en\/knowledge-center\/en-iso-14698-to-en-17141\/","og_site_name":"Lighthouse Worldwide Solutions","article_publisher":"https:\/\/www.facebook.com\/Lighthouse.Worldwide.Solutions","article_modified_time":"2022-12-20T19:49:20+00:00","og_image":[{"width":1000,"height":714,"url":"https:\/\/www.golighthouse.com\/en\/wp-content\/uploads\/2022\/12\/Changing-Standards-Smaller.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.golighthouse.com\/en\/knowledge-center\/en-iso-14698-to-en-17141\/","url":"https:\/\/www.golighthouse.com\/en\/knowledge-center\/en-iso-14698-to-en-17141\/","name":"Getting From EN ISO 14698 to EN 17141","isPartOf":{"@id":"http:\/\/www.golighthouse.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.golighthouse.com\/en\/knowledge-center\/en-iso-14698-to-en-17141\/#primaryimage"},"image":{"@id":"https:\/\/www.golighthouse.com\/en\/knowledge-center\/en-iso-14698-to-en-17141\/#primaryimage"},"thumbnailUrl":"https:\/\/www.golighthouse.com\/en\/wp-content\/uploads\/2022\/12\/Changing-Standards-Smaller.png","datePublished":"2022-12-14T05:48:00+00:00","dateModified":"2022-12-20T19:49:20+00:00","description":"EN ISO 14698 was voted to be obsolete and replaced with EN 17141. Now, there is an international push to adopt the singular standards put forward in EN 17141.","breadcrumb":{"@id":"https:\/\/www.golighthouse.com\/en\/knowledge-center\/en-iso-14698-to-en-17141\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.golighthouse.com\/en\/knowledge-center\/en-iso-14698-to-en-17141\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.golighthouse.com\/en\/knowledge-center\/en-iso-14698-to-en-17141\/#primaryimage","url":"https:\/\/www.golighthouse.com\/en\/wp-content\/uploads\/2022\/12\/Changing-Standards-Smaller.png","contentUrl":"https:\/\/www.golighthouse.com\/en\/wp-content\/uploads\/2022\/12\/Changing-Standards-Smaller.png","width":1000,"height":714},{"@type":"BreadcrumbList","@id":"https:\/\/www.golighthouse.com\/en\/knowledge-center\/en-iso-14698-to-en-17141\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.golighthouse.com\/en\/"},{"@type":"ListItem","position":2,"name":"Knowledge Center","item":"https:\/\/www.golighthouse.com\/en\/knowledge-center\/"},{"@type":"ListItem","position":3,"name":"Getting From EN ISO 14698 to EN 17141"}]},{"@type":"WebSite","@id":"http:\/\/www.golighthouse.com\/en\/#website","url":"http:\/\/www.golighthouse.com\/en\/","name":"Lighthouse Worldwide Solutions","description":"","publisher":{"@id":"http:\/\/www.golighthouse.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"http:\/\/www.golighthouse.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"http:\/\/www.golighthouse.com\/en\/#organization","name":"Lighthouse Worldwide Solutions","url":"http:\/\/www.golighthouse.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"http:\/\/www.golighthouse.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.golighthouse.com\/en\/wp-content\/uploads\/2022\/11\/211317000-1-R1-LWS-Logo-Black-on-White.png","contentUrl":"https:\/\/www.golighthouse.com\/en\/wp-content\/uploads\/2022\/11\/211317000-1-R1-LWS-Logo-Black-on-White.png","width":217,"height":36,"caption":"Lighthouse Worldwide Solutions"},"image":{"@id":"http:\/\/www.golighthouse.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/Lighthouse.Worldwide.Solutions"]}]}},"_links":{"self":[{"href":"https:\/\/www.golighthouse.com\/en\/wp-json\/wp\/v2\/knowledge-center\/9777","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.golighthouse.com\/en\/wp-json\/wp\/v2\/knowledge-center"}],"about":[{"href":"https:\/\/www.golighthouse.com\/en\/wp-json\/wp\/v2\/types\/knowledge-center"}],"version-history":[{"count":18,"href":"https:\/\/www.golighthouse.com\/en\/wp-json\/wp\/v2\/knowledge-center\/9777\/revisions"}],"predecessor-version":[{"id":10232,"href":"https:\/\/www.golighthouse.com\/en\/wp-json\/wp\/v2\/knowledge-center\/9777\/revisions\/10232"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.golighthouse.com\/en\/wp-json\/wp\/v2\/media\/9778"}],"wp:attachment":[{"href":"https:\/\/www.golighthouse.com\/en\/wp-json\/wp\/v2\/media?parent=9777"}],"wp:term":[{"taxonomy":"kc_format","embeddable":true,"href":"https:\/\/www.golighthouse.com\/en\/wp-json\/wp\/v2\/kc_format?post=9777"},{"taxonomy":"kc_topics","embeddable":true,"href":"https:\/\/www.golighthouse.com\/en\/wp-json\/wp\/v2\/kc_topics?post=9777"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}