1104LD | 2014 | 3014 | 5014 | 3104 | 5104 | 5104V | |||||||
Specifications |
|||||||||||||
Size Range | 0.10 - 1.0 μm | 0.2 - 2μm | 0.3 - 25μm | 0.5 - 25μm | 0.3 - 25μm | 0.5 - 25μm | |||||||
Channel Sizes | Standard: 0.10, 0.15, 0.2, 0.25, 0.3, 0.5, 0.7, 1.0 μm | Standard: 0.2, 0.3μm Standard: 0.2, 0.5μm Optional: 0.2, 0.3, 0.5, 1.0μm Optional: 0.2, 0.3, 0.5, 2.0μm |
Standard: 0.3, 0.5μm Standard: 0.3, 1.0μm Standard: 0.3, 3.0μm Optional: 0.3, 0.5, 1.0, 5.0μm |
Standard: 0.5, 5.0μm Optional: 0.5, 1.0, 5.0, 10.0μm Optional: 0.5, 5.0, 10.0, 25.0μm |
Standard: 0.3, 0.5μm Optional: 0.3, 0.5, 0.7, 1.0μm; 0.3, 0.5, 1.0, 5.0μm; Optional: 0.3, 0.5, 5.0, 10.0μm |
Standard: 0.5, 5.0μm; 0.5, 10.0μm Optional: 0.5, 1.0, 5.0, 10.0μm; 0.5, 5.0, 10.0, 25.0μm |
|||||||
Flow Rate | 1.0 CFM (28.3 LPM) | 0.1 CFM (2.83 LPM) | 1.0 CFM (28.3 LPM) | ||||||||||
Laser Source | Laser Diode | ||||||||||||
Zero Count Level | < 1 Count / 5 minutes (meets specifications of JIS B 9921 and reporting requirements of ISO 21501-4 Annex C) | ||||||||||||
Concentration Limits | 1,000,000 particles /ft3 (34,300,000/m3 ) @ 10% coincidence loss | 4,000,000 Particles/ft3@10% Coincidence loss suitable for ISO classes 1-8 cleanrooms | 1,000,000 Particles/ft3@10% Coincidence loss suitable for ISO classes 1-8 cleanrooms | ||||||||||
Calibration | NIST Traceable ISO 21501-4 Compliant and Accredited ISO 17025 | ||||||||||||
Vacuum Requirements | External Vacuum >18” (45.72 cm) of Hg | ||||||||||||
Air Flow | Internally Monitored | ||||||||||||
Communication Modes | Serial - 485 Modbus RJ45 | ||||||||||||
LED Indicators | Power, Flow, Service, Sampling | ||||||||||||
Data Storage | Rotating Buffer, 2000 Records | ||||||||||||
Supporting Software | LMS XChange, Lighthouse Monitoring System; LMS Express; Express RT; LMSNet | ||||||||||||
Environmental Sensors | - | (Optional) Temperature/Relative Humidity Probe 32 - 122F (0-50C)+/-1F (0.5C); 0 - 100% RH +/-2% | - | ||||||||||
Connector | RJ45 | Industrial RJ45 | |||||||||||
Power | 24 VDC | ||||||||||||
Dimensions | 10.5” (w) x 7.65” (h) x 3.35” (d) [26.67 x 19.43 x 8.51 cm] | 1.7”(l) x 4.2”(w) x 3”(h) [4.3 x 10.7 x 7.6 cm] | 1.7"(l) x 4.2"(w) x 3"(h) [4.3 x 10.7 x 7.6 cm] | 1.7”(l)x4.2”(w)x3”(h) [4.3x10.7x7.6cm] | 5.42” (l) x 2.14” (w) x 3.58” (h), [13.76 cm (l) x 5.43 cm (w) x 9.09 cm (h)] | ||||||||
Environmental Conditions |
|||||||||||||
Operating | 50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing | ||||||||||||
Storage | 14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing |
Incorporating the latest laser optical particle counting technology, Lighthouse designed the Remote 5014 for continuous trouble-free operation. With a minimum sensitivity range of 0.5 µm and a flow rate of 0.1 CFM, the Remote 5014 provides continuous real-time data collection at a cost-effective price per point.
Using an external vacuum source, the Remote 5014 provides versatile mounting options and can be installed where space is at a premium. The Remote 5014 will integrate seamlessly into extensive facility monitoring and management systems.
Key Features:
SERVICE & CALIBRATION