Solair

How - To - Videos

Solair 1100/3100/5100 Tutorial Series | Configure Sample Settings

Solair 1100/3100/5100 Tutorial Series | Configure Alarm Settings

Solair 1100/3100/5100 Tutorial Series | Configure Security Settings

Reports Function

Locations Function

Get a Quote

Accessories

High Pressure Diffuser Ported Version
High Pressure Diffuser Vented Version
universal manifold
Universal Manifold
scanair pro
Scan Air

Unmatched Versatility

Your Solair Particle Counter Can Do It All

Besides being the best portable in the market, the Solair can be connected to a manifold and used in a real time monitoring system. Add a Scan Air Pro filter scanning probe and do filter integrity testing. High pressure gas adapters allow you to do particle testing in ultra-pure gasses. Integrate environmental sensors and you have the world’s most versatile portable particle counter.

The SOLAIR incorporates our extreme life laser diode technology sensor to produce the industry’s longest laser diode life of 20+ year MTTF (based on continuous 24/7 operation).  Using a new, lighter extended-life battery and external AC adapter, the SOLAIR 3350 is even more portable. The SOLAIR features one of the industry’s best user interfaces (UI) to configure and operate the instrument with intuitive ICON-driven screens and menus that are simple and easy to learn and use.

The SOLAIR can store up to 3,000 records of particle count data from up to 8 particle channels and the configurable recipe database can store up to 50 recipes for sampling and reports.  All data can be quickly and reliably transferred to a computer, a Facility Monitoring System or a Building Automation System.  Secure data transfer (per 21 CFR Part 11) to a USB flash drive can be accomplished by using the Lighthouse secure data transfer feature and LMS Express or Express RT software to read it. Flexible communications with these instruments is made possible by the integrated Ethernet, RS-485, USB and USB flash drive interfaces.  SOLAIR  is designed, manufactured and calibrated to ISO 21501-4 to ensure particle-counting accuracy.

Key Features:

  • 0.1 µm – 5.0 µm Particle Size Range
  • 1.0 CFM (28.3 LPM) flow rate
  • Up to 8 particle sizes
  • Number 1 in class for versatility
  • Industry’s Best User Interface
  • ISO 21501-4 Compliant
  • One of the lightest portables on the market
  • Stainless steel construction
  • 21 CFR Part 11 compliant secure data transfer via USB flash drive
  • Report wizard for cleanroom pass/fail reports: FS-209E, ISO 14644-1 (2015 version), and EU GMP Annex 1
  • Multiple communication interfaces: USB, RS-485, Ethernet, and USB flash drive
  • 5.7-inch color TFT touch screen display
  • 3,000 record data storage memory
  • 50-record configurable recipe database
  • Multiple language support:  English, French, German, Italian, Spanish, Chinese, Russian, Japanese, Korean

Key Features:

  • 0.3 µm – 25.0 µm Particle Size Range
  • 1.0 CFM (28.3 LPM) flow rate
  • Up to 8 particle sizes
  • Number 1 in class for versatility
  • Industry’s Best User Interface
  • ISO 21501-4 Compliant
  • One of the lightest portables on the market
  • 20-year MTTF laser lifespan
  • Stainless steel construction
  • 21 CFR Part 11 compliant secure data transfer via USB flash drive
  • Report wizard for cleanroom pass/fail reports: FS-209E, ISO 14644-1 (2015 version)  and EU GMP Annex 1
  • Multiple communication interfaces; USB, RS-485, Ethernet and USB flash driv.
  • 5.7-inch color TFT touch screen display
  • 3000 record data storage memory
  • 50-record configurable recipe database
  • Multiple-language support: English, French, German, Italian, Spanish, Chinese, Russian, Japanese, Korean

Key Features:

  • 0.3 µm – 25.0 µm Particle Size Range
  • 100 LPM flow rate
  • Up to 8 particle sizes
  • Number 1 in class for versatility
  • Industry’s Best User Interface
  • ISO 21501-4 Compliant
  • One of the lightest portables on the market
  • 20-year MTTF laser lifespan
  • Stainless steel construction
  • 21 CFR Part 11 compliant secure data transfer via USB flash drive
  • Report wizard for cleanroom pass/fail reports: FS-209E, ISO 14644-1 (2015 version)  and EU GMP Annex 1
  • Multiple communication interfaces; USB, RS-485, Ethernet and USB flash driv.
  • 5.7-inch color TFT touch screen display
  • 3000 record data storage memory
  • 50-record configurable recipe database
  • Multiple-language support: English, French, German, Italian, Spanish, Chinese, Russian, Japanese, Korean

Key Features:

  • 0.5 µm – 25.0 µm Particle Size Range
  • 1.0 CFM (28.3 LPM) flow rate
  • Up to 8 particle sizes
  • Number 1 in class for versatility
  • Industry’s Best User Interface
  • ISO 21501-4 Compliant
  • One of the lightest portables on the market
  • 20-year MTTF laser lifespan
  • Stainless steel construction
  • 21 CFR Part 11 compliant secure data transfer via USB flash drive
  • Report wizard for cleanroom pass/fail reports: FS-209E, ISO 14644-1 (2015 version)  and EU GMP Annex 1
  • Multiple communication interfaces; USB, RS-485, Ethernet and USB flash driv.
  • 5.7-inch color TFT touch screen display
  • 3000 record data storage memory
  • 50-record configurable recipe database
  • Multiple-language support: English, French, German, Italian, Spanish, Chinese, Russian, Japanese, Korean

Key Features:

  • 0.5 µm – 100.0 µm Particle Size Range
  • 1.0 CFM (28.3 LPM) Flow Rate
  • Simultaneous Display of up to 6 Particle Sizes
  • Number 1 in class for versatility
  • Industry’s Best User Interface
  • ISO 21501-4 Compliant
  • One of the lightest portables on the market
  • 20-year MTTF laser lifespan
  • Stainless steel construction
  • 21 CFR Part 11 compliant secure data transfer via USB flash drive
  • Report wizard for cleanroom pass/fail reports: FS-209E, ISO 14644-1 (2015 version)  and EU GMP Annex 1
  • Multiple communication interfaces; USB, RS-485, Ethernet and USB flash driv.
  • 5.7-inch color TFT touch screen display
  • 3000 record data storage memory
  • 50-record configurable recipe database
  • Multiple-language support: English, French, German, Italian, Spanish, Chinese, Russian, Japanese, Korean
  •  

Ensuring Purity and Performance: The Critical Role of Particle Contamination Monitoring in Industrial Gases

Discover how our advanced particle counters safeguard the integrity and efficiency of key processes by detecting particle contaminants in essential gases like Argon, Helium, CO2, Ammonia, Nitrogen, and other inert gases. Ensuring the highest standards in industries from pharmaceuticals to semiconductors.
  • (Ar) (He) (NH 3 ) (N) (CO 2 ) OTHER

    Argon

    Contaminants in argon can affect its inertness, leading to unwanted reactions in processes where argon is used to create a stable, non-reactive environment. This is crucial in applications like shielding gases in welding or inert atmospheres in metal manufacturing.

  • (He) (NH 3 ) (N) (CO 2 )

    Helium

    Due to its small atomic size, helium is highly sensitive to particle contamination. Contaminants can affect its efficacy as a cooling medium in cryogenics and its purity in gas chromatography, impacting the accuracy and efficiency of these processes.

  • (He) (NH 3 ) (N) (CO 2 )

    CO2

    Particle contaminants in CO2 can affect its properties as a supercritical fluid, impacting its use in extraction and cleaning processes. In applications where CO2 is used for carbonation or as a refrigerant, purity is essential for both product quality and process efficiency.

  • (He) (NH 3 ) (N) (CO 2 )

    Nitrogen

    Nitrogen is often used for creating inert atmospheres in various industries. Particle contaminants in nitrogen can introduce impurities into these processes, affecting everything from the quality of pharmaceutical products to the integrity of electronic components in semiconductors

  • (He) (NH 3 ) (N) (CO 2 )

    Ammonia

    In semiconductor manufacturing, impurities in ammonia can lead to defects in nitride films, affecting the performance of electronic devices. In chemical synthesis, contaminants can alter reaction pathways, leading to undesired products or yields.

  • (He) (NH 3 ) (N) (CO 2 ) OTHER

    Other Inert Gases

    Other Inert Gases Inert gases like neon, xenon, and krypton are used in specialized applications where their specific properties are crucial. Particle contaminants can alter these properties, thereby affecting the performance in applications like lighting, imaging, or as carrier gases.

Instrument Files

Title
Download
Data Sheet – Solair 1100LD
Download
Operating Manual – Solair 1100LD Gen E
Download
Operating Manual – Solair 3100, 5100, Boulder Counter Gen E
Download
Data Sheet – Solair 3100, 3350, 5100, Boulder Counter
Download
Operating Manual – Solair 3350 Gen E
Download

Accessory Files

Title
Download
Data Sheet – Universal Manifold II
Download
Data Sheet – High Pressure Diffuser
Download
Operating Manual – High Pressure Diffuser
Download

HPD - Ported

Features: 

  • Allows sampling of Inert Pressurized Gasses
  • 0.1, 1.0, 2.0, 3.5 CFM Models available
  • Pressure Ranges from 5 – 150 PSI (depending on flow rate)
  • Ported & Exhausted versions available
  • Compatible with Handheld, Solair & ApexZ Instruments
  • 1.30″ (3.3 cm) at max diameter x 11.76″ [29.9 cm] max length
  • 1.50 lbs (0.68 kg)

HPD - Vented

Features: 

  • Allows sampling of Inert Pressurized Gasses
  • 0.1, 1.0, 2.0, 3.5 CFM Models available
  • Pressure Ranges from 5 – 150 PSI (depending on flow rate)
  • Ported & Exhausted versions available
  • Compatible with Handheld, Solair & ApexZ Instruments
  • 1.30 (3.3 cm) at max diameter x 10.65″ [27 cm] max length
  • 1.1 lbs (0.5 kg)