TECHNICAL DETAILS

  3013 2016 3016 5016 3016 IAQ

Specifications

Size Range 0.3 - 10.0 µm 0.2 - 2.0 μm 0.3 - 25.0 μm 0.5 - 25.0 μm 0.3 - 10.0 μm
Channel Sizes Standard: 0.3, 0.5, 5.0µm
Optional: (specify at time of order) 0.3, 0.5, 0.7, 1.0, 2.5, 5.0, 10.0µm
0.2, 0.3, 0.5, 0.7, 1.0, 2.0 μm Standard: 0.3, 0.5, 0.7, 1.0, 2.0, 5.0 μm
Standard: 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 μm
Standard: 0.3, 0.5, 0.7, 1.0, 2.5, 5.0 μm
Standard: 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm
Optional: 0.3, 0.5, 1.0, 5.0, 10.0, 25.0 μm
Standard: 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 μm
Optional: 0.5, 1.0, 3.0, 5.0, 10.0, 25.0 μm
Standard: 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm
Counting Efficiency 50% @ 0.3μm, 100% for particles >0.45μm (per JIS B 9921) 50% @ 0.2 μm; 100% for particles > 0.3 μm (per ISO 21501-4) 50% @ 0.3 μm; 100% for particles > 0.45 μm (per ISO 21501-4) 50% @ 0.5 μm; 100% for particles > 0.75 μm (per ISO 21501-4) 50% @ 0.3 μm; 100% for particles > 0.45 μm (per ISO 21501-4)
Flow Rate 0.1 CFM (2.83 LPM)
Laser Source Laser Diode Extreme Life Laser Diode with >20 Years MTTF
Zero Count Level <1 count / 5 minutes (per JIS B 9921) <1 count / 5 minutes (per ISO 21501-4)
Concentration Limits 4,000,000 particles / ft³ @ 5% coincidence loss
Calibration NIST traceable, ISO 21501-4 compliant Meets ISO 21501-4 Calibration using NIST Traceable PSL Spheres, DMA and Condensation Particle Counter
Count Modes Automatic, Beep, Concentration Automatic, Manual, Beep, Concentration, Cumulative/Differential Automatic, Manual, Beep, Concentration, Cumulative/Differential, Mass Concentration
Data Storage 1,000 sample records, rotating
buffer
3,000 Sample Records, Rotating Buffer (includes particle and environmental data, location and time)
Communication Modes USB Output port RS-232 via RJ-45 to a PC or an Optional Printer
Supporting Software LMS XChange; LMS Express LMS XChange; LMS Express; LMS Express RT; LMS Pharma; LMS Standard; CRQWin
Environmental Sensors - Temperature/Relative Humidity Probe:0-150°F (-17.8 to 65.6°C) ±1.8°F @ 77°F, 0-100% ± 5% @ 33%
Touch Screen Display 2,7" 128 x 64 OLED Screen 3.5” (8.89 cm), Color TFT
Reports - FS-209E, ISO-14644-1 & EC GMP
Mass Concentration - 1 μg/m³ Approximate Mass Concentration
Alarms - Internal, Adjustable Alarm Buzzer. Alarms on Counts, Low Battery or Sensor Failure
Sample Inlet Isokinetic Sampling Probe
Sample Output - Internally Filtered to HEPA Standards (>99.97% @ 0.3 μm)
Vacuum Source Internal Twin Diaphragm Pump Internal Pump, Automatic Flow Control
Enclosure Molded ABS High Impact Injection Molded Plastic
Power Internal Lithium Ion Battery External Power Supply: 12VDC, 1.25A
Battery Li-Ion, Internal & Rechargeable
Less than 2 hours to fully charge
Up to 8 Hours of Continual Use
Li-Ion, Removable & Rechargeable
Dimensions 4.2” (w) x 6.5” (h) x 1.9” (d) [10.5 x 16.5 x 4.8 cm] 8.75” (l) x 5.0” (w) x 2.5” (h) [22.23 x 12.7 x 6.35 cm]
Weight 1.5 lbs (0.68 kg) 2.2 lb (1kg)
Languages English (U.S.), Deutsch, Espanol, Italiano, Francois, Russian, Japanese, Korean and Chinese.

Environmental Conditions

Operating 50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing
Storage 14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing

Accessories

Included LMS XChange Data Transfer Software; Operating Manual on CD; USB Interface Cable; AC Adapter; Purge Filter; Hard Carrying Case Operating Manual on CD; Removable Battery; Direct Mount Isokinetic Sample Probe; Purge Filter; Temperature / Relative Humidity Probe; Power Supply; Power Cord; LMS XChange and LMS Express Software
Optional LMS Express Software; Printed Operating Manual Carrying Case; Isokinetic Sample Probe with 6 ft. tubing (extends Isokinetic sample input); Additional Li-Ion Batteries; External Battery Charger w/ AC & Car Adapter; Thermal Printer and Cable; Mini Manifold; Printed Operating Manual

GET A QUOTE

First Name (*)
Last Name (*)
Company Name (*)
Email (*)
Phone (*)
Address (*)
(*) Required Fields
Message (*)
Security Code
Security Code ImageRefresh Button
(*)

Handy, Man

Particle Counting at your Fingertips

Lighthouse’s Handheld Particle Counters are feature-rich instruments that are ideal for spot-checking inside of your critical environments or Indoor Air Quality applications. With its compact size and weight along with its sleek handle, you can utilize this unit with ease. These units provide immediate results that allow you to proactively monitor your environment.
Particle count data is truly at your fingertips.

Handy, Man Image

PRODUCT CONFIGURATOR

Handheld 3013 Image

Handheld 3013

Using an ergonomic and lightweight design, the Lighthouse Handheld 3013 is ideal for use where a smaller lightweight handheld...

Handheld 2016 Image

Handheld 2016

The ergonomically designed and lightweight Lighthouse Handheld 2016 particle counter features a minimum sensitivity of 0.2...

Handheld 3016 Image

Handheld 3016

The ergonomically designed and lightweight Lighthouse Handheld 3016 particle counter features a minimum sensitivity of 0.3...

Handheld 3016-IAQ Image

Handheld 3016-IAQ

Our ergonomically designed and lightweight Lighthouse Handheld 3016-IAQ is the most advanced handheld particle...

Handheld 5016 Image

Handheld 5016

The ergonomically designed and lightweight Lighthouse Handheld 5016 particle counter features a minimum sensitivity of 0.5...