Incorporating the latest in laser optical particle counting technology, Lighthouse designed the REMOTE LPC 0.3μm liquid particle counter for continuous trouble-free operation.
With a sensitivity of 0.3μm at a fl ow rate of 100 ml per minute, the REMOTE LPC 0.3μm provides real-time continuous data collection at a cost-effective price per point.
These compact liquid particle counters provide versatile mounting options and can be installed where space is at a premium.
The REMOTE LPC 0.3μm integrates seamlessly into large facility monitoring and management systems and transfers up to 2 channels of simultaneous particle count data using the LWS 4-20mA protocol.
Designed and built by Lighthouse – a name you can trust.
Lighthouse is an ISO 9001:2008 Registered Company.
Remote LPC 0.3 (4-20mA Output) Datasheets
Letter Size – Lo Res A4 Size – Lo Res
Letter Size – Hi Res A4 Size – Hi Res
- Size Range 0.3 – 3.0 μm
- 2 Channel Sizes
- Sample Flow Rate of 100 ml per Minute
- Stainless Steel Enclosure
- Status Indicators
- External Alarm Output
- 4-20mA Output
- Interfaces with Facility Monitoring Systems
- Compact Size
- Designed for Reliability
- 2 Year Warranty
- Installs in Limited Space
- Cost Effective Price Per Point
- Easy System Integration
- International Support
- Low Cost of Ownership
- Quantifying Particle Concentration in High Purity Water Systems
- Filter Efficiency Particle Measurements
- Trend Analysis at Lower Particle Concentrations
- Episodic Particle Event Tracking and Alarming
- Manufacturing Process Control
- Continuous System Particle Monitoring
- Process Bath Monitoring
- DI Water Monitoring
- Parts Cleanliness Testing
- Water Quality Monitoring
Specifications
| Size Range: |
0.3 – 3.0 µm |
| Channel Sizes: |
Standard: 0.3, 0.5μm Optional: 0.3, 0.7μm; 0.3, 2.0μm; 0.3, 3.0μm |
| Laser Source: |
Laser Diode |
| Flow Rate: |
100ml/min |
| Calibration: |
NIST Traceable |
| Communication Modes: |
RS-232 via RJ45 to PC, 4-20mA |
| LED Indicators: |
Power, Service, Sampling |
| Concentration Limit: |
4,000 counts/ml @ 5% Coincidence Error |
| External Alarm Output: |
Normal Open Dry Contact Rated 0 – 60v AC/DC 1 Amp |
| Enclosure: |
Stainless Steel |
| Sample Inlet/Outlet Connection: |
1/4” Flaretek™ |
| Sample Temperature: |
32 - 302°F (0 – 150 °C) |
| Sample Pressure: |
150 PSI |
| Wetted Surface Materials: |
Quartz, PTFE, PFA |
| Power: |
24V DC |
| Dimensions: |
5.7”(L) x 5.2”(W) x 3”(H) [14.47 x 13.2 x 7.6 cm] |
| Weight: |
3.5 lbs (1.58 kg) |
| Environmental Conditions |
| Operating: |
50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing |
| Storage: |
14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing |
| Accessories |
| Included: |
Operating Manual on CD; Power Supply; tubing; Flow Cell cleaning brush; Micro90® Solution |
| Optional: |
Printed Operating Manual; Flow Control Device; Sample Tubing; Cabling; Flaring Kit; Flare nuts; LPC Stand with Flow Meter mount; LPC Flowmeter - Aluminum; LPC Flow Meter - Teflon™ PFA; Remote Mounting Bracket. |
| Chemicals that can be used with the Remote LPC 0.3 |
| CHEMICAL |
SYMBOL |
| Water |
H20 |
| Deionized Water |
H2O, DI H2O |
| Nitric Acid 70% |
HNO3, 70% |
| Sulphuric Acid 96% |
H2SO4 |
| Hydrochloric Acid 37% |
HCL |
| Ammonium Hydroxide 29% |
NH4OH |
| Hydrogen Peroxide 30% |
H2O2 |
| Phosphoric Acid 86% |
H3PO4 |
| Isopropyl Alcohol |
IPA |
| Acetone |
C3H6O |
| N-methyl Perryiodine |
NMP |
| Chemicals that CAN NOT be used with the Remote LPC 0.3 |
| CHEMICAL |
SYMBOL |
| Nitric Acid 100% |
HNO3 100% |
| Ammonium Flouride |
NH4F |
| Hydrofloric Acid 50% |
HF 50% |
| Hydrofloric Acid 5% |
HF 5% |
| Hydrofloric Acid 0.5% |
HF 0.5% |
| Buffered Hydrofloric Acid or Buffered Oxide Etch |
BHF, BOE |
| Tetramethylammonium Hydroxide |
TMAH |