Incorporating the latest in laser optical particle counting technology, Lighthouse designed the REMOTE 2014P airborne particle counter for continuous troublefree operation.
With sensitivity of 0.2 at a flow rate of 0.1 CFM (2.83 LPM), the REMOTE 2014P provides real-time continuous data collection at a cost-effective price per point. Using an internal vacuum source, the compact REMOTE 2014P particle counter can be installed where space is at a premium.
The REMOTE 2014P integrate seamlessly into large facility monitoring and management systems and transfer up to 6 channels of simultaneous particle count data using RS-485 Modbus.
Designed and built by Lighthouse, a name you can trust.
 |
 |
 |
 |
 |
 |
| Internal Vacuum Pump |
Direct Mount Isokinetic Probe |
RJ45 Connector |
LED Status |
Alarm Relay |
Four 4-20mA Inputs |
Remote 2014P Datasheets
Letter Size – Hi Res A4 Size – Hi Res
- 0.2 - 2μm Range
- 0.1 CFM (2.83 LPM) Flow Rate with Internal Pump
- Up to 6 Channels of Simultaneous Data
- All Models Meet JIS Standards
- Compact Size
- Stainless Steel Enclosure
- Up to Four 4-20 mA Inputs (30 mW)
- LED Status Indicators
- External Alarm Connector
- RS-485 Modbus
- Facility Monitoring System Interface
- Flow-controlled Internal Vacuum Pump
- Designed for Reliability
- 2 Year Warranty
- Installs in Limited Space
- Cost Effective Price per Point
- Proven Data Integrity
- Proven Reliability
- Continuous Real-Time Data
- Easy System Integration
- International Support
- Low Cost of Ownership
Specifications
| Size Range: |
0.2 - 2.0 μm |
| Channel Sizes: |
Standard: 0.2, 0.3, 0.5, 1.0 μm |
| Counting Efficiency: |
50% @ 0.2 μm; 100% for particles > 0.3 μm (per JIS) |
| Flow Rate: |
0.1 CFM (2.83 LPM) |
| Laser Source: |
Laser Diode |
| Zero Count Level: |
|
| Concentration Limits: |
2,000,000 Particles / ft3 @ 5% Coincidence Loss |
| Calibration: |
NIST Traceable |
| Vacuum Requirements: |
Internal Vacuum Pump |
| Air Flow: |
Internally Monitored and Controlled |
| Communication Modes: |
RS-485 MODBUS |
| LED Indicators: |
Power, Flow, Service, Sampling |
| Data Storage: |
3,000 Samples |
| Connectors: |
RJ45 |
| Supporting Software: |
LMS XChange; Lighthouse Monitoring System; LMS Express, Express RT and RT+; LMSNet |
| Up to Four 4-20 mA Inputs: |
Can be used with the Lighthouse standard 4-20 mA Temperature/Relative Humidity, Air Velocity or Differential Pressure Probes or any other 4-20 mA device |
| External Alarm Output: |
Normally Open Dry Contact Rated 0-60 V AC/DC 1 Amp |
| Enclosure: |
Stainless Steel |
| Power: |
24 VDC |
| Dimensions: |
9”(l) x 3.5”(w) x 6”(h) [22.86 x 8.89 x 15.24 cm] |
| Weight: |
3.19 lbs (1.45 kg) |
Conditions
| Operating: |
50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing |
| Storage: |
14°F to 122°F (-10°C to 50°C) / Up to 98% non-condensing |
Accessories
| Included: |
Operating Manual on CD; LMS XChange; Power Supply; Power Cord |
| Optional: |
Printed Operating Manual; REMOTE Display; REMOTE Display 10-foot Extension Cable; Network Adapter; Wireless Network Adapter; Isokinetic Sampling Probe; Sample Tubing; Data Cabling; Purge Filter; Temperature/Relative Humidity Probe; Air Velocity Probe; Differential Pressure Probe; RS-232 Interface Cable and Adapter; LMS Express, Express RT, RT+ and LMSNet software |
| Sample System Integration |
 |